Industrial Properties Hazard classification ranges from low-to-high depending on tenant uses, process water, chemical handling, irrigation, fire systems, cooling towers, and any auxiliary water sources. Many purveyors treat unknown or mixed-tenant industrial sites conservatively.
Industrial real estate properties include:
- Warehouses & distribution centers (logistics, fulfillment, cold storage)
- Light manufacturing / assembly
- Flex industrial (office + warehouse)
- Industrial parks with multiple tenants and frequent tenant improvements
- Contractor yards (landscape, plumbing, construction staging)
- R&D / prototyping within industrial suites (varies widely)
Because contamination consequence and uncertainty are high, Industrial properties are frequently required to install premises containment. Many purveyors require RP containment for industrial/multi-tenant properties where tenant uses are variable or include potential chemical/process hazards. Even where DC containment is allowed for warehouse-only uses, specific on-site systems (fire additives, cooling towers, process equipment, chemical injection) can drive RP requirements.
As a bonded and insured licensed contractors and certified backflow testing professionals specializing in the installation, testing and repair of commercial backflow prevention assemblies, Backflow Test Pros guarantees top-tier workmanship at the most competitive rates, provides backflow repair coverage and includes 2-year installation warranty to help you meet and exceed your Industrial Tenant Property backflow installation, testing, repair compliance requirements.
Call for Your Free Industrial Property Compliance Review to Qualify for
Installation Warranty, Best Value Testing, Repair Coverage & Multi-Device Discounts
Many purveyors default industrial and multi-tenant industrial to RP containment unless the owner can demonstrate low-hazard use and controls. Hazard classification ranges from low-to-high depending on tenant uses, process water, chemical handling, irrigation, fire systems, cooling towers, and any auxiliary water sources. Many purveyors treat unknown or mixed-tenant industrial sites conservatively.
Industrial Property Features that Trigger Strict Backflow Inspection and Enforcement
- Tenant uses can change frequently and may be unknown at the meter level
- Many tenants use hoses, washdown, utility sinks, and chemical cleaners
- Some tenants introduce process equipment requiring water connections
- Industrial sites often have booster pumps, elevated piping, and complex manifolds
- Many properties include fire services, irrigation, and mechanical systems that trigger separate requirements
Common hazard drivers include:
- Process water connections (manufacturing, equipment cooling, rinsing)
- Chemical handling (solvents, acids/bases, detergents, disinfectants)
- Compressed air/water stations and maintenance wash areas
- Cooling towers/evaporative condensers (chemical feed)
- Boilers/hydronic loops (chemical additives, glycol)
- Contractor yards (fertilizers, pesticides, truck washdown, tanks)
- Auxiliary water sources (wells, reclaimed water, storage tanks)
- Frequent tenant improvements with plumbing changes
At a minimum, most water purveyors require the following protection levels:
A. Domestic Potable Service (Premises Containment)
Typical outcomes (vary by purveyor and property profile):
- DC (Double Check Valve Assembly) may be allowed for warehouse-only facilities with low-hazard use and no process water/chemicals.
- RP (Reduced Pressure Principle Assembly) is commonly required for:
- multi-tenant industrial parks (tenant uses variable/unknown)
- any manufacturing/process water use
- chemical storage/handling or washdown
- cooling towers/boilers with chemical additives
- any history of cross-connection issues
- any auxiliary water source or complex interconnections
B. Fire Protection Services (Separate Fire Meter/Service)
- DCDA/DCVA often allowed for “clean” fire sprinkler systems
- RPDA required where antifreeze or other additives exist
- Some purveyors require RPDA when the overall site is classified high hazard or when system conditions are uncertain
C. Irrigation Services (If Present)
- PVB commonly used/allowed for standard irrigation (if local standards allow)
- RP required if chemical injection, booster pumps, auxiliary water sources, or higher hazard determinations exist
Industrial Tenant Property owners are responsible for installation, testing, repair, and ongoing compliance.
Hiring a certified backflow tester to perform Industrial Property backflow prevention installation, testing and repair in a timely manner is key to ensuring compliance with state and municipal water department regulations.
Backflow Test Pros is 100% dedicated to ensuring your property meets local water authority Industrial Property backflow installation, testing and repair requirements so you can avoid civil penalties and ensure your water is not turned off for noncompliance.
Ensure you're fully compliant with specific city, county and water districts backflow prevention requirements
Ensure your backflow assembly installation clears local permitting requirements and plans approvals
Ensure your installed backflow device is USC FCCCHR approved and meets hazard level requirements
Free initial backflow certification testing, same-day report submittal and backflow repair coverage
We provide the best value in Industrial Property backflow prevention installations, testing and repair services by combining competitive pricing with premium service, warranty coverage and unmatched expertise.
Backflow Test Pros is an AWWA Certified Backflow Tester and Certified Backflow Tester with County Health Departments across Southern California. As a CA State licensed contractor and AWWA Certified backflow specialists, our team of experienced backflow experts work with County Health Boards and Municipal Water Departments throughout Southern California to protect our water and prevent backflow contamination.
Industrial properties are frequently required to install premises containment. Many purveyors require RP containment for industrial/multi-tenant properties where tenant uses are variable or include potential chemical/process hazards. Even where DC containment is allowed for warehouse-only uses, specific on-site systems (fire additives, cooling towers, process equipment, chemical injection) can drive RP requirements.
Understanding the types of retail property shopping center backflow installation, testing, and maintenance requirements helps you avoid civil liabilities and ensures water safety compliance.
Backflow Risk at RIndustrial Tenant Property Arise from the Following Facility Features:
- Tenant uses can change frequently and may be unknown at the meter level
- Many tenants use hoses, washdown, utility sinks, and chemical cleaners
- Some tenants introduce process equipment requiring water connections
- Industrial sites often have booster pumps, elevated piping, and complex manifolds
- Many properties include fire services, irrigation, and mechanical systems that trigger separate requirements
Common hazard drivers include:
- Process water connections (manufacturing, equipment cooling, rinsing)
- Chemical handling (solvents, acids/bases, detergents, disinfectants)
- Compressed air/water stations and maintenance wash areas
- Cooling towers/evaporative condensers (chemical feed)
- Boilers/hydronic loops (chemical additives, glycol)
- Contractor yards (fertilizers, pesticides, truck washdown, tanks)
- Auxiliary water sources (wells, reclaimed water, storage tanks)
- Frequent tenant improvements with plumbing changes
Even with containment, many properties require Industrial Property–Specific Internal (Point-of-Use) internal controls—especially where owners provide common-area water or where tenants add equipment.
A. Hose Bibbs, Utility Sinks, and Common-Area Washdown (Highest Frequency Findings)
Risk drivers:
- submerged hoses in mop buckets or chemical containers
- hose connections near loading docks, trash enclosures, and wash areas
- tenants adding sprayers, splitters, and chemical injectors
Typical controls:
- Anti-siphon hose bibbs / hose bibb vacuum breakers
- Prohibit submerged hoses and unapproved attachments
- Secure/label common-area water points to prevent misuse
B. Tenant Process Equipment Connections (Property-Dependent)
Examples: parts washers, plating rinse tanks, equipment cooling lines, pressure washers, mixing tanks, food or beverage production, medical device manufacturing, labs, etc.
Risk drivers:
- direct connections to tanks/process vessels
- chemical additives or contaminants
- pressurized systems creating backpressure
Typical expectations:
- Purveyor review for process water connections
- Approved backflow protection (often RP or air gap depending on process hazard)
- No cross-connections between process loops and potable supply
C. Cooling Towers / Evaporative Equipment (If Present)
Risk drivers:
- chemical feed (biocides, scale inhibitors)
- recirculating system makeup water tie-in
Typical expectations:
- Makeup water protected as required (commonly RP)
- Chemical feed system arranged to prevent cross-connection pathways
- Often treated as high hazard even if the rest of the site is “warehouse”
D. Boilers / Hydronic Loops / Equipment Cooling Loops (If Present)
Risk drivers:
- chemical additives, glycol
- pressurized loops and backpressure potential
- makeup water tie-ins
Typical expectations:
- Makeup water protected per purveyor/system design (often RP)
- No unapproved bypasses
- Clear mechanical-room labeling and access
E. Auxiliary Water Sources / Storage Tanks / Reclaimed Water (If Present)
Risk drivers:
- cross-connection between potable and nonpotable sources
- tank backfeed scenarios
- complex valving and bypass arrangements
Typical expectations:
- Strict physical separation and approved backflow prevention at interties (often air gap and/or high-level protection)
- Purveyor involvement is typically mandatory
- Unapproved interconnections are treated as serious violations
F. Industrial Wash Bays / Vehicle Wash Areas (If Present)
Risk drivers:
- detergent/chemical use
- hose submergence and sprayers
- booster pumps
Typical expectations:
- Containment RP often required
- Hose connections protected; chemical injection systems reviewed and protected appropriately
Industrial Tenant Property Backflow Violation Enforcement & Penalties
Industrial and multi-tenant properties often face strict enforcement because tenant activities are difficult for purveyors to monitor without containment. Local water purveyors typically may:
- issue notices and compliance deadlines
- require cross-connection surveys and on-site inspections
- assess administrative fees/penalties (varies)
- terminate water service for failure to install/test/maintain required assemblies or unresolved cross-connections
Additional Civil Liabilities
Industrial Tenant Property owners and tenants are exposed to additional civil liabilities resulting from contamination in the event of failure to prevent backflow into the potable water resources used by other parties.

Because industrial properties include many High-Risk tenant categories it is important that you perform an extensive cross connection and backflow prevention compliance review to avoid penalties, water disruptions and civil liabilities. Many purveyors require more frequent testing for high hazard sites or repeated failures.
Common Industrial Property Deficiencies That Trigger Enforcement
- Missing or incorrect containment device for industrial classification (RP expected)
- Overdue annual testing (domestic/fire/irrigation)
- Unapproved bypass piping around containment device
- Hose bibbs without vacuum breakers (loading docks, wash areas, trash enclosures)
- Tenants adding process equipment without purveyor review
- Cooling tower/boiler makeup lines lacking required protection
- Evidence of auxiliary water sources or tanks connected without approvals
- Assemblies inaccessible due to pallets/racking/locked cages
- RP relief discharge flooding mechanical rooms or vaults
Call Us for Your Industrial Property Backflow Compliance Review to Ensure
You are Not in Violation of State and Local backflow Prevention Requirements
1. Confirm hazard classification with the purveyor (warehouse-only vs industrial/multi-tenant).
2. Verify containment requirement (DC vs RP—RP is common for multi-tenant/variable use).
3. Inventory site systems: fire service type, irrigation, cooling towers, boilers, wash bays, process water, auxiliary sources.
4. Ensure hose bibbs and common-area water points are protected with vacuum breakers/anti-siphon devices.
5. Require tenant review/approval process for any new water-connected equipment.
6. Test all assemblies annually and after install/repair/relocation/modification.
7. Submit reports on time; maintain a centralized compliance binder for multi-tenant sites.
8. Repair failures promptly and retest.
9. Re-evaluate after tenant improvements, new tenants, or mechanical plant upgrades.